【交换机】两设备直连,互ping管理地址,规律性丢包

您所在的位置:网站首页 交换机ping设备丢包 【交换机】两设备直连,互ping管理地址,规律性丢包

【交换机】两设备直连,互ping管理地址,规律性丢包

2024-07-07 02:04| 来源: 网络整理| 查看: 265

S86#ping 192.168.33.253 ntimes 1000

Sending 1000, 100-byte ICMP Echoes to 192.168.33.253, timeout is 2 seconds:

  < press Ctrl+C to break >

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

Success rate is 99 percent (991/1000), round-trip min/avg/max = 1/1/20 ms

可以看出,ping规律性丢包,大约是每100个包丢一个,1%的丢包率;

在RGOS10.4及以后的软件中,NFPP中的icmp-guard的功能默认开启,这样保护cpu不受攻击,所以如果执行长ping会规律性丢包,项目实施或者测试中需要注意。

该现象是我们软件实现上的正常结果,如果需要关闭icmp-guard,实现100%不丢包,参考如下命令:

S86#conf t

S86(config)#nfpp

S86(config-nfpp)#no icmp-guard enable

S86(config-nfpp)#end

注意:如果双方都是我司设备,需要两边设备都关闭icmp-guard。

 