Core Shear Strength |
您所在的位置:网站首页 › hypersizer › Core Shear Strength |
Open topic with navigation Failure Analysis > Sandwich Panels > Core Shear Strength Core Shear Strength AID Analysis Name 107 Shear Strength, X (Longitudinal) direction {Hexcel} 108 Shear Strength, Y (Transverse) direction {Hexcel} 109 Shear Strength, InteractionThe shear strength failure calculation is a comparison of the shear strength in the core to the out-of-plane shear loads induced by either cantilevered loads or pressure loads – the latter is common in aerospace applications. In the case of coupling HyperSizer with FEA, the shear loads in the panels, Qx and Qy are extracted directly from the element forces of the FEA results. The shear strength allowable is the shear strength in the core multiplied by a shear strength correction factor, which is derived from vendor data.
See the HME document for more information.