Advertisement
Table of Contents
1
Precautions
2
Specifications
3
Model Description
4
User Interface Instructions
5
Copy /Key Lock /Zero-Clear Function
6
Output Mode Description
7
Dimensions/Assembly Instructions
8
Zero-Clear Funtion
Download this manual
DPS Series
Digital Display Pressure Switch
Precautions
Do not drop 、 knock or apply excessive impact while handling.Otherwise
could cause damage and a malfunction.
The tensile strength of the cord is 60N.Applying a greater pulling
force on it can cause a malfunction.
Do not exceed the screw-in torque of 7N m when installing piping.
Exceeding this value may cause malfunctioning of the sensor.
Do not use it with corrosive and/or flammable gases or liquids.
Please use it within rated pressure range.
Turn off the power before connecting the wires.
Don't use in an environment with spattering liquid of oil or solvent.
Separate power lines from high voltage lines,avoiding wiring in the
same conduit with these lines.
Specifications
Model
DPSN1-01、DPSN1-10、DPSP1-01、DPSP1-10
12 to 24VDC ±10%,Ripple(p-p)≤10%
Voltage
Input power
Current
45 mA or less
consumption
fluid type
Non-corrosive gas
DPSN1(P1)-01:-100kPa to 100kPa
Measurement
range
DPSN1(P1)-10:-100kPa to 1000kPa
DPSN1(P1)-01:200kPa
Pressure
Withstand
range
pressure
DPSN1(P1)-10:1500kPa
Measurement
±2% F.S. ±1 digit
error
Repeative
±0.2% F.S.
accuracy
Temperature
±3% F.S.(Base 25℃,Range 0 to 50℃ )
error
Display
Double row LCD display
Type
4-digit measurement, 3.5-digit setting
Display
Output
Color
2-color LCD (Red/Green)
Display
100ms、250ms、500ms、1000ms
period
DPSN1:Built-in two sets of NPN output
Output group
DPSP1:Built-in two sets of PNP output
NPN:Maximum applied voltage 30V/100mA,
Transistor
Retained voltage
|