Corsair HX1200i ’80 Plus Platinum’ Power Supply review |
您所在的位置:网站首页 › hx1200i拆解 › Corsair HX1200i ’80 Plus Platinum’ Power Supply review |
![]() Today we take a look at one of the latest Corsair power supplies – the fully modular HX 1200i. This new power supply has been created with high efficiency and low noise emissions in mind. It will slot in above the HX1000i that we reviewed back in August last year as the flagship model in this specific range. At £199.99 inc vat should this be shortlisted for a new system build this year?
Corsair say they have carefully selected every component in the creation of the HXi to eliminate noise. They have placed special effort into improving the windings of transformers/coils in the design. Vibrations can occur if components are not wound properly – leading to what many users are calling ‘coil whine’. A fairly common problem with some power supplies on the market, even today. Corsair seem confident in the new design – they are offering a full 7 year warranty with the HXi power supplies. Corsair HX1200i Features: Corsair Link™ Integration for monitoring performance and adjustment of fan speed and multi-rail/single rail mode. 80 PLUS® Platinum efficiency, delivering 92% energy efficiency at real world load conditions. ZeroRPM mode for fanless operation at low loads and outstanding noise reduction. 140mm thermally controlled fluid dynamic bearing fan spins up as needed. Fully Modular low profile cables for easy installation, less clutter, and helps maximize airflow through your computer’s chassis. Engineered to meet maximum power output at a server-grade 50C temperature rating. Fan self-test switch to determine fan functionality even before installation. The latest ATX12V v2.4 and EPS 2.92 standards and is backward compatible with ATX12V 2.2, 2.31 and ATX12V 2.01 systems. 4th generation Intel® Core™ processor Ready (Intel Haswell and Z87 motherboards). Over-voltage protection, under-voltage protection, and short circuit protection, over power protection, over temperature protection provide maximum safety to your critical system components. Safety and Agency Approvals: FCC, ICES, CE, UL / CUL, CSA, C-Tick/RCM, TUV, CB, CU, KC Mark, RoHS, WEEE, RoHS (China), REACH
The HX1200i passed our ‘screwdriver' test without a hitch. This involves running the head of a Philips head driver down the side of the chassis with light to medium force. The paintwork stood up to the stress test. After all, how many times have you accidentally connected with a power supply during a system build?
The Corsair Digital Link connector works with the Corsair Link software using either a mini USB connector or a I2C connector. The fan test button is included so the user can check the fan is still operational – useful as most of the time it will not be running at all. The LED turns green when the USB header is connected and the power supply is functioning properly. When the link is active, the lights will rotate between green and red colours. If it holds a solid red, it has lost connectivity completely.
The Corsair HX1200i Platinum Modular power supply can deliver 100A via the +12V rail. It can deliver all of its available power across the +12V rail.
Corsair say this fan was designed with blades shaped to move more air while creating less noise. The blades are balanced to help prevent resonance at higher spin speeds. This fan is a fluid dynamic bearing design, superior to most sleeve or ball bearing units on the market. Corsair have enhanced the motor core and windings in the bearing for better low noise performance at reduced speeds.
Correctly testing power supplies is a complex procedure and KitGuru have configured a test bench which can deliver up to a 2,000 watt DC load. Due to public requests we have changed our temperature settings – previously we rated with ambient temperatures at 25C, we have increased ambient temperatures by 10c (to 35c) in our environment to greater reflect warmer internal chassis conditions. We use combinations of the following hardware: • SunMoon SM-268 • CSI3710A Programmable DC load (+3.3V and +5V outputs) • CSI3711A Programmable DC load (+12V1, +12V2, +12V3, and +12V4) • Extech Power Analyzer • Extech MultiMaster MM570 digital multimeter • SkyTronic DSL 2 Digital Sound Level Meter (6-130dBa) • Digital oscilloscope (20M S/s with 12 Bit ADC) • Variable Autotransformer, 1.4 KVA DC Output Load RegulationCombined DC Load +3.3V +5V +12V +5VSB -12V A V A V A V A V A V 100W 1.55 3.34 1.75 5.05 6.65 12.22 0.50 5.02 0.20 -12.07 200W 3.13 3.34 3.50 5.05 13.50 12.18 1.00 5.02 0.20 -12.07 400W 6.40 3.33 7.05 5.04 27.50 12.14 1.50 5.02 0.30 -12.07 600W 9.80 3.33 10.77 5.04 41.70 12.12 2.00 5.01 0.30 -12.07 800W 13.25 3.33 14.55 5.04 56.40 12.08 2.50 5.01 0.50 -12.08 1000W 16.55 3.32 15.75 5.03 71.40 12.06 3.00 5.01 0.60 -12.08 1200W 22.01 3.32 22.01 5.00 85.00 12.02 3.60 5.00 0.80 -12.08Load regulation is very good indeed, holding within 2%. Corsair HX1200i Maximum Load 1344 WattsWe managed to get another 144 watts from the power supply before the protection circuitry kicked in. The supply was undamaged and it was ready to fire up again when we dropped the load to a more realistic level. Next we want to try Cross Loading. This basically means loads which are not balanced. If a PC for instance needs 500W on the +12V outputs but something like 30W via the combined 3.3V and +5V outputs then the voltage regulation can fluctuate badly. Cross Load Testing +3.3V +5V +12V -12V +5VSB A V A V A V A V A V 1190W 4.0 3.34 3.0 5.05 88.0 12.00 0.2 -12.04 0.50 5.01 240W 19.0 3.33 22.0 4.99 2.5 12.15 0.2 -12.03 0.50 5.00The Corsair HX1200i power supply delivered a great set of results in the demanding Cross load test, as shown above. We then used an oscilloscope to measure AC ripple and noise present on the DC outputs. We set the oscilloscope time base to check for AC ripple at both high and low ends of the spectrum. ATX12V V2.2 specification for DC output ripple and noise is defined in the ATX 12V power supply design guide. ATX12V Ver 2.2 Noise/Ripple Tolerance Output Ripple (mV p-p) +3.3V 50 +5V 50 +12V1 120 +12V2 120 -12V 120 +5VSB 50Obviously when measuring AC noise and ripple on the DC outputs the cleaner (less recorded) means we have a better end result. We measured this AC signal amplitude to see how closely the unit complied with the ATX standard. AC Ripple (mV p-p) DC Load +3.3V +5V +12V 5VSB 100W 10 10 15 5 200W 15 10 15 10 400W 15 10 15 10 600W 15 10 20 10 800W 15 10 25 15 1000W 15 15 30 15 1200W 15 15 30 20Fantastic results – all rails hold well within the industry rated tolerance levels. Efficiency (%) 100W 85.8 200W 88.9 400W 93.0 600W 94.1 800W 93.8 1000W 92.6 1200W 92.2The overall efficiency results are excellent, peaking at 94.1% at 600W. This drops to 92.4% efficiency at full load, a very impressive result overall. We take the issue of noise very seriously at KitGuru and this is why we have built a special home brew system as a reference point when we test noise levels of various components. Why do this? Well this means we can eliminate secondary noise pollution in the test room and concentrate on components we are testing. It also brings us slightly closer to industry standards, such as DIN 45635. Today to test the Power Supply we have taken it into our acoustics room environment and have set our SkyTronic DSL 2 Digital Sound Level Meter (6-130dBa) one meter away from the unit. We have no other fans running so we can effectively measure just the noise from the unit itself. As this can be a little confusing for people, here are various dBa ratings in with real world situations to help describe the various levels. KitGuru noise guide 10dBA – Normal Breathing/Rustling Leaves 20-25dBA – Whisper 30dBA – High Quality Computer fan 40dBA – A Bubbling Brook, or a Refrigerator 50dBA – Normal Conversation 60dBA – Laughter 70dBA – Vacuum Cleaner or Hairdryer 80dBA – City Traffic or a Garbage Disposal 90dBA – Motorcycle or Lawnmower 100dBA – MP3 Player at maximum output 110dBA – Orchestra 120dBA – Front row rock concert/Jet Engine 130dBA – Threshold of Pain 140dBA – Military Jet takeoff/Gunshot (close range) 160dBA – Instant Perforation of eardrum Noise (dBA) 100W |