DELTA DTB4824 TEMPERATURE CONTROLLER INSTRUCTION SHEET

您所在的位置:网站首页 dtb4848说明书 DELTA DTB4824 TEMPERATURE CONTROLLER INSTRUCTION SHEET

DELTA DTB4824 TEMPERATURE CONTROLLER INSTRUCTION SHEET

#DELTA DTB4824 TEMPERATURE CONTROLLER INSTRUCTION SHEET | 来源: 网络整理| 查看: 265

Advertisement

Quick Links Download this manual See also: User Manual Original version 2006-12-195011628704-DBE4http://www.delta.com.tw/industrialautomation/Series Temperature ControllerInstruction SheetThank you very much for purchasing DELTA B Series. Please read this instruction sheet before using your B series toensure proper operation and please keep this instruction sheet handy for quick reference.PrecautionsDANGER! Caution! Electric Shock!Do not touch the AC terminals while the power is supplied to the controller to prevent an electric shock.1.Make sure power is disconnected while checking the unit inside.2.The symbolindicates that this Delta B Series Temperature Controller is protected throughout by DOUBLE3.INSULATION or REINFORCED INSULATION (equivalent to Class II of IEC 536).WARNING!This controller is an open-type temperature controller. Make sure to evaluate any dangerous application in whicha serious human injury or serious property damage may occur.Always use recommended solder-less terminals: Fork terminal with isolation (M3 screw, width is 7.0mm (6.0mm for1.DTB 4824), hole diameter 3.2mm). Screw size: M3 x 6.5 (With 6.8 x 6.8 square washer). Screw size for DTB4824: M3x 4.5 (With 6.0 x 6.0 square washer). Recommended tightening torque: 0.4 N.m (4kgf.cm). Applicable wire:2Solid/twisted wire of 2 mm, 12AWG to 24AWG. Please be sure to tighten them properly.Do not allow dust or foreign objects to fall inside the controller to prevent it from malfunctioning.2.Never modify or disassemble the controller.3.Do not connect anything to the “No used” terminals.4.Make sure all wires are connected to the correct polarity of terminals.5.Do not install and/or use the controller in places subject to:6.•Dust or corrosive gases and liquid.•High humidity and high radiation.•Vibration and shock.•High voltage and high frequencyMust turn power off when wiring and changing a temperature sensor.7.Be sure to use compensating wires that match the thermocouple types when extending or connecting the8.thermocouple wires.Please use wires with resistance when extending or connecting a platinum resistance thermometer (RTD).9.Please keep the wire as short as possible when wiring a platinum resistance thermometer (RTD) to the controller and10.please route power wires as far as possible from load wires to prevent interference and induced noise.This controller is an open-type unit and must be placed in an enclosure away from high temperature, humidity, dripping11.water, corrosive materials, airborne dust and electric shock or vibration.Please make sure power cables and signals from instruments are all installed properly before energizing the controller,12.otherwise serious damage may occur.Please do not touch the terminals in the controller or try to repair the controller when power is applied to prevent an13.electric shock.Wait at least one minute after power is disconnected to allow capacitors to discharge, and please do not touch any14.internal circuit within this period.Do not use acid or alkaline liquids for cleaning. Please use a soft, dry cloth to clean the controller.15.This instrument is not furnished with a power switch or fuse. Therefore, if a fuse or power switch is required, install the16.protection close to the instrument. Recommended fuse rating: Rated voltage 250 V, Rated current 1 A. Fuse type:Time-lag fuseNote: This controller does not provide overcurrent protection. Use of this product requires that suitable overcurrent17.protection device(s) must be added to ensure compliance with all relevant electrical standards and codes. (Rated 250V, 15 Amps max). A suitable disconnecting device should be provided near the controller in the end-use installation.Display, LED & PushbuttonsPV Display: to display the process value or parameter type.SV Display: to display the set point, parameter operation read value,manipulated variable or set value of the parameter.AT:Auto-tuning LED,flashes when the Auto-tuning operation is ON.OUT1/OUT2: Output LED ights when the output is ON., l:Function key. Press this key to select the desired function mode andconfirm a setting value.:Mode key. Press this key to set parameters within function mode.OOOOC, F :Temperature unit LED.C : CelsiusF : FahrenheitALM1 ~ ALM3 : Alarm output LED, lights when ALM1/ALM2/ALM3 is ON.:Down key. Press this key to decrease values displayed on the SVdisplay. Hold down this key to speed up the decrements.:Upkey. Press this key to increase values displayed on the SV display.Hold down this key to speed up the incremental action.Ordering InformationDTB 1 2 3 4 5 67DTB SeriesDTB: Delta B Series Temperature Controller4824: 1/32 DIN W48 × H24mm4896: 1/8 DIN W48 × H96mm1 2 3 4Panel Size (W×H)4848: 1/16 DIN W48 × H48mm9696: 1/4 DIN W96 × H96mmR: Relay output, SPDT (SPST: 1/16 DIN and 1/32 DIN size), 250VAC, 5A5V: Voltage pulse output, 14V +10﹪~ -20﹪(Max. 40mA)1st Output Group SelectionC: DC current output , 4 ~ 20m AL: Linear voltage output, 0~5V, 0~10VdcR: Relay output, SPDT (SPST: 1/16 DIN and 1/32 DIN size), 250VAC, 5A62nd Output Group SelectionV: Voltage pulse output, 14V +10﹪~ -20﹪(Max. 40mA)None: No EVENT input , No CT (Current transformer)7E: EVENT input is provided, No CT (Current transformer)EVENT Inputs / CT function (Optional)T: CT (Current transformer) is provided, No EVENT inputV: Valve control.Note 1: DTB4824 series: no optional function provided and no extra alarm output supported, but user can set 2nd output as alarm mode.Note 2: DTB4848 series: only one alarm output when optional function supported, but user can set 2nd output as 2nd alarm output.Note 3: “Valve control” with feedback selection is only available for DTB4896RRV, DTB9696RRV.SpecificationsInput Voltage100 to 240VAC 50/60HzOperation Voltage Range85% to 110% of rated voltagePower Consumption5VA max.Memory ProtectionEEPROM 4K bit (non-volatile memory (number of writes: 100,000)Display Method2 line x 4 character 7-segment LED display Process value(PV): Red color, Set point(SV): Green colorThermocouple: K, J, T, E, N, R, S, B, L, U, TXKSensor Type3-wire Platinum RTD: Pt100, JPt100Analog input: 0 ~ 5V, 0 ~ 10V, 0 ~ 20 m A, 4 ~ 20 m A, 0 ~ 50mVControl ModePID, ON/OFF, Manual or PID program control (Ramp/Soak control)Relay output: SPDT (SPST: 1/16 DIN and 1/32 DIN size), Max. load 250VAC, 5A resistive loadVoltage pulse output: DC 14V, Max. output current 40mAControl OutputCurrent output: DC 4 ~ 20m A output (Load resistance: Max. 600Ω)Linear voltage output: 0 ~ 10VDisplay Accuracy0 or 1 digit to the right of the decimal point (selectable)Sampling RateAnalog input: 150 msec/ per scan Thermocouple or Platinum RTD: 400 msec/per scanRS-485 CommunicationMODBUS ASCII / RTU communication protocol2Vibration Resistance10 to 55Hz, 10m/sfor 10min, each in X, Y and Z directions2Shock ResistanceMax. 300m/ s, 3 times in each 3 axes, 6 directions ooAmbient Temperature0C to +50CooStorage Temperature-20C to +65CAltitude2000m or lessRelative Humidity35% to 80% (non-condensing)Temperature Sensor Type & Temperature RangeInput Temperature Sensor TypeRegister ValueLED DisplayTemperature Range0 ~ 50mV Analog Input17-999 ~ 99994 ~ 20mA Analog Input16-999 ~ 99990 ~ 20mA Analog Input15-999 ~ 99990V ~ 10V Analog Input14-999 ~ 99990V ~ 5V Analog Input13-999 ~ 9999oPlatinum Resistance (Pt100)12-200 ~ 600CoPlatinum Resistance (JPt100)11-20 ~ 400CoThermocouple TXK type10-200 ~ 800CoThermocouple U type9-200 ~ 500CoThermocouple L type8-200 ~ 850CoThermocouple B type7100 ~ 1800CoThermocouple S type60 ~ 1700CoThermocouple R type50 ~ 1700CoThermocouple N type4-200 ~ 1300CoThermocouple E type30 ~ 600CoThermocouple T type2-200 ~ 400CoThermocouple J type1-100 ~ 1200CoThermocouple K type0-200 ~ 1300CΩNote 1: An internal 249precision resistor for the current input is built-in, please refer to the item “How To Set Up Current Input”.Note 2:(Operation mode) must be set if user wish to specify decimal point position. Except for the thermocouple B, S, R type, the decimal point positions of allthe other thermocouple type input sensors can be set.The default range of analog input is -999 ~ 9999. For example, when a 0 ~ 20mA analog input is selected as the input temperature sensor type, -999 indicates 0mA and9999 indicates 20mA. If change the input range to 0 ~ 2000, then 0 indicates 0mA and 2000 indicates 20mA. One display scale is equal to 0.01mA.OperationThere are three modes of operation: operation, regulation and initial setting. When power is applied, controller gets intothe operation mode. Press thekey to switch to regulation mode. If thekey is pressed for more than 3 seconds,controller will switch to the initial setting mode. Pressing thekey while in the regulation mode or initial setting mode,forces the controller to return to the operation mode. PV/SV: Sets the temperature set point and displays the temperatureprocess value. Usekeys to set the temperature set point.Setting method: While in any function mode, press thekey to select the desired function and use thekeys tochange settings. Presskey to save the changes. The next flow chart shows how to switch for settings and internalfunctions:Presskey less than 3 secPresskey more than 3 secRegulation ModeOperation ModeInitial Setting ModePresskeyPresskeyRegulation ModeOperation ModeInitial Setting ModeAuto-tuningUsekey toSet input typeset temperature set point(Set in PID control and RUN mode)PressPressPress4 groups PID modes (n=0~3). When n=4,Set temperature unitControl setting RUN or STOPPID control is auto regulated.do not display when analog inputPressPressPressPD control offsetStart pattern setting (PIDsettingSet upper-limit ofprogram control and(When PID control is ON and Ti=0,temperature rangeTime setting.set the value of PdoF.PressPressPressDecimal point position selectionSet lower-limit ofHeating hystereisis setting(except for B, S, R type, all thetemperature range(Set in ON/OFF control mode)other types can be set)PressPressPressUpper-limit alarm 1Select control modeCooling hystereisis setting(This parameter is available only when(See "Pattern and set Editing(Set in ON/OFF control mode)ALA1 function enables)selection" for detail)PressPressPressHeating/CoolingLower-limit alarm 1orSelect heating/cooling controlcontrol cycle setting(This parameter is available only whenor dual loop output control(Set in PID control mode)ALA1 function enables)PressPressPressControl cycle settingUpper-limit alarm 2of 2nd output groupAlarm 1 mode setting(This parameter is available only when(Set in PID control and Dual LoopALA2 function enables)output control mode)PressPressPressP value of 1st & 2nd output groupLower-limit alarm 2during dual loop output controlAlarm 2 mode setting(This parameter is available only whenP value of 2nd output group =ALA2 function enables)(P value of 1st output group)xPressPressPressUpper-limit alarm 3Dead Band (Set in Dual LoopAlarm 3 mode setting(This parameter is available only whenoutput control mode)ALA3 function enables)PressPressPressSwitch setting for feedbackLower-limit alarm 3Set system alarmsignal of valve. (Display when(This parameter is available only whenvalve control is ON)ALA3 function enables)PressPressPressAutomatically regulateCommunication write functionSetting lock modefeedback value.enable/disable(Display when valve control is ON)PressPressPressPressDisplay and adjust output valueTime setting for valve fromASCII, RTU communicationof 1st output groupfull close to full open. (Display when(Display in PID control mode and manualformat selectionvalve control is ON)RUN mode)PressPressPressDisplay and adjust output valueValve Dead Band setting.Communication addressof 2nd output groupsetting(Display in dual loop PID control mode and(Display when valve control is ON)manual RUN mode)PressPressPressPress Upper-limit regulation ofIn case of using an external CT,the controller displays the currentCommunication baudvalve output with feedback tovalue being measured by CT, ifrate settingcontroller. (Display when valvethe control output is ONsignal feedback function is ON)PressPressto return to set target temperaturePressLower-limit regulation ofValve output with feedback.valve output with feedback toData length setting(Display when valve feedbackcontroller. (Display when valvefunction is ON)signal feedback function is ON)PressPressPressDA value feedback of valve.Regulate temperatureParity bit setting(Display when valve feedbackdeviation valuefunction is ON)PressPressPressBack to target temperatureRegulate upper-limit of analogoutput valueStop bit setting(The setting display when analog output)Pressto return input type settingPressRegulate lower-limit of analogoutput value(The setting display when analog output)Pressto return to auto-tuning mode1 Scale = 2.8uA = 1.3mV for tuning output valuePID mode selection: any one of 4 groups PID modes (n = 0 ~ 3) can be selected. When n = 4, program will automatically select 1 group PID that is most useful for targettemperature.Select n=0~4 todecide PID mode.PID setting: n=0.PressPID setting: n=3.Press0~3 groups PIDPressProportion band setting: n=0.Proportion band setting: n=3.PressPressTi setting: n=3. PressTi setting: n=0. PressTd setting: n=0. PressTd setting: n=3. PressIntegral deviation setting: n=3.Integral deviation setting: n=0.AT setting.AT setting.PressPressback to PID deviation settingback to PID deviation settingPattern and step editing selection: editinparameter. The following display is the example operation of pattern No. 0.Select desired editing patternSelect actual step No. whenEdit temperature of step No. 0numberprogram control is executingof pattern No. 0select OFFPressPressselect numberPressEdit time of step No. 0 ofSet additional execution cycleExitpattern and step editing selectionnumber(0 to 99)pattern No. 0, unit is hh.mmSwitch toand continue settingPressPressSet step No. 07 in orderSet link pattern, OFF indicatesthe program endEdit temperature of step No. 7Pressto return pattern No. editingof pattern No. 0modePressEdit time of step No. 7 ofpattern No. 0, unit is hh.mmPressto set actual step No.Dual Loop Output Control (Heating/Cooling Control)Temperature control can be achieved either by heating or cooling. InDead bandDTB series, heating and cooling can be operated simultaneously(Dual Loop output control) to perform temperature control. When DualHeating hysteresisCooling hysteresisLoop output control are used, two control outputs must be connectedONto the heating and cooling devices. Please refer to the following forHeatingCoolingthe operation:OFFPV: This parameter is used to select heating or cooling action ifSet pointoperate either heating or cooling function in this controller. WhenFigure 1. Outputoperation of ON/OFF controlduring dual loop output controlselecting, 1st output group is heating (reverse) control, andwhen selecting, 1st output group is cooling (forward) control.Dead band: deadOutputAt this moment, 2nd output group is regarded as an alarm output. Ifband width=positiveuser selector, it indicates that user can operate DualLoop output control function in this controller. When selecting,1st output group is heating (reverse) control and 2nd output group isHeatingCoolingPV0cooling (forward) control. When selecting, 1st output group isSet pointcooling (forward) control and 2nd output group is heating (reverse)Figure 2. PIDcontrol,Dead Band is positivecontrol.In DTB series, P (Proportional Band), I(Integral Time) andD(Derivative Time) parameters are automatically set by using theAuto-tuning (AT) function.Dead band: deadOutput: This parameter is for the control mode that must be Dualband width=negativeLoop output control with PID control method configured. The value ofP, I and D of 1st output group can be set immediately. The P value of2nd output group is equal to (P value of 1st output group) xHeatingCoolingand the value of I and D of 2nd output group are the same as thePV0value of I and D of 1st output group.Set pointFigure 3. PIDcontrol,Dead Band is negative: Dead Band, shown as the following figure 1, 2 and 3. Thisparameter sets an area in which the heating and cooling controloutput is 0 centering around the set point in a Dual Loop outputcontrol mode.: Settings lock. To avoid incorrect operation, two key lock functions are provided.: Lock 1 can lock allsettings. All parameters and temperature settings can be locked to disable changes.: Lock 2 can lock settingsexcept the SV (Set point) value. All parameters and temperature settings can be locked with the exception of the SV value.Pressandkey simultaneously, the “Lock” status can be released.Alarm OutputsThere are up to three groups of alarm outputs and each group allows thirteen alarm types in the initial setting mode. Thealarm output is activated whenever the process temperature value (PV) is getting higher or lower than the set point ofalarm limit.Set ValueAlarm TypeAlarm Output Operation0Alarm function disabledOutput is OFFDeviation upper- and lower-limit:ON1This alarm output operates when PV value is higher than the setting value SV+(AL-H) orOFFSVlower than the setting value SV-(AL-L).SV-(AL-L)SV+(AL-H)ONDeviation upper-limit:2OFFThis alarm output operates when PV value is higher than the setting value SV+(AL-H).SVSV+(AL-H)ONDeviation lower-limit:3OFFThis alarm output operates when PV value is lower than the setting value SV-(AL-L).SVSV-(AL-L) Previous Page Next Page 1 2

Advertisement



【本文地址】


今日新闻


推荐新闻


CopyRight 2018-2019 办公设备维修网 版权所有 豫ICP备15022753号-3