由于缆线故障、导致Brocade交换机端口盖板 |
您所在的位置:网站首页 › chg故障 › 由于缆线故障、导致Brocade交换机端口盖板 |
问题描述
在switchshow下、交换机端口状态为联机
/fabos/bin/switchshow : Index Slot Port Address Media Speed State Proto ============================================================ 129 4 33 708100 id N32 Online FC F-Port 10:00:00:10:9b:e7:9c:fc 在porterrshow下、 link failureloss sync enc_out, crc err, crc g_eof, c3timeout Tx, pcsuncorr 系统会报告多个和错误以及其他介质错误、例如和错误。/fabos/cliexec/porterrshow : frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err 100: 14.1k 5.8k 2.2k 964 932 0 0 32 3.9g 6 12 0 4.4k 0 0 0 0 0 0 /fabos/cliexec/porterrshow : frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err 129: 20.6k 20.7k 0 0 0 0 0 0 0 9 2.5k 0 7.2k 0 0 9 0 1.1k 26.0k /fabos/cliexec/porterrshow: frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err 37: 2.3g 6.4g 0 0 0 0 0 0 0 53 2 0 4 0 0 53 0 0 0 sfpshow 报告Rx和Tx 值处于最佳范围。RX Power: 1.4 dBm (1365.3uW) TX Power: -0.4 dBm (910.2 uW) sfpshow 报告Rx值过低。RX Power: -15.1 dBm (30.7 uW) TX Power: -1.7 dBm (678.9 uW) portshow 输出确认端口为联机且处于In-Sync状态、 LR_IN大于OLS_OUT、这表示问题描述是switchport的外部端口。 portshow 37 portDisableReason: None [..] portState: 1 Online Protocol: FC portPhys: 6 In_Sync portScn: 32 F_Port FC Fastwrite: OFF Interrupts: 48 Link_failure: 2 Frjt: 0 Unknown: 6 Loss_of_sync: 0 Fbsy: 0 Lli: 48 Loss_of_sig: 4 Proc_rqrd: 159 Protocol_err: 0 Timed_out: 0 Invalid_word: 0 Tx_unavail: 0 Invalid_crc: 0 Delim_err: 0 Address_err: 0 Lr_in: 6 Ols_in: 2 Lr_out: 2 Ols_out: 3 Cong_Prim_in: 0 在下 Fabriclog,可以看到这两个端口在闪烁。 Fabriclog: Switch 0; Tue Oct 11 12:34:12 2022 IST (GMT+5:30) 12:34:12.020011 SCN Port Offline;rsn=0x2,g=0x530 D2,P0 D2,P0 15 NA 12:34:12.020017 *Removing all nodes from port D2,P0 D2,P0 15 NA 12:34:12.112102 SCN Port Offline;rsn=0x0,g=0x532 D2,P0 D2,P0 127 NA 12:34:12.112108 *Removing all nodes from port D2,P0 D2,P0 127 NA 12:36:40.840204 SCN LR_PORT(0);g=0x530 D2,P0 D2,P0 15 NA 12:36:40.860941 SCN Port Online; g=0x530,isolated=0 D2,P0 D2,P1 15 NA 12:36:40.861044 Port Elp engaged D2,P1 D2,P0 15 NA 12:36:40.861057 *Removing all nodes from port D2,P0 D2,P0 15 NA 规则 defALL_32GSWL_SFPRXP_63 并 defALL_OTHER_F_PORTSSTATE_CHG_5 在 errdump 日志下触发 loss signal、以及、 link failures 和 frame timeout detected 错误。2022/10/11-12:41:00, [MAPS-1004], 46328, SLOT 1 | FID 128, INFO, XXX, SFP 3/15, Condition=ALL_32GSWL_SFP(RXP3), Current Value:[LOSS_SIGNAL, 378 LOS], RuleName=defALL_PORTSLOSS_SIGNAL_3, Dashboard Health. 2021/10/23-23:38:47, [MAPS-1003], 55690, SLOT 1 | FID 128, WARNING, Fabric1, slot10 port31, U-Port 10/31, Condition=ALL_PORTS(LF/min>3), Current Value:[LF, 4], RuleName=defALL_PORTSLF_3, Dashboard Category=Port Health. 2021/10/23-04:24:46, [PORT-1003], 53615, SLOT 1 | FID 128, WARNING, Fabric1, Port 223 Faulted because of many Link Failures. 2020/04/08-21:35:56, [C3-1014], 2556, CHASSIS, WARNING, Brocade6510, Link Reset on Port S0,P8(12) vc_no=0 crd(s)lost=12 auto trigger. 2020/04/09-09:03:42, [C3-1014], 2557, CHASSIS, WARNING, Brocade6510, Link Reset on Port S0,P8(12) vc_no=0 crd(s)lost=12 auto trigger. 2023/10/15-01:03:18, [AN-1014], 589, FID 128, INFO, SAN32G_FME1937T016_C2A1_F1, Frame timeout detected, tx port 37 rx port 15, sid 650900, did 632501, timestamp 2023-10-15 01:03:18 . 2023/10/15-01:03:18, [LOG-1000], 594, FID 128, INFO, SAN32G_FME1937T016_C2A1_F1, Previous message repeated 5 time(s). RuleName=defALL_32GSWL_SFPRXP_63 当Rx电源开始降级且指示上游问题描述I、e SFP或cable 出现故障时触发 |
CopyRight 2018-2019 办公设备维修网 版权所有 豫ICP备15022753号-3 |