一、普通模式(该机硬盘没有做磁盘阵列)

1、fdisk -l 查看你的硬盘编号,如sda,sdb 等

2、smartctl --all /dev/sda

[html] view plain copy   smartctl --all /dev/sda #该命令centos自带  

 

[html] view plain copy   [root@localhost ~]# smartctl --all /dev/sda   smartctl 5.43 2012-06-30 r3573 [x86_64-linux-2.6.32-504.el6.x86_64] (local build)   Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net      === START OF INFORMATION SECTION ===   Device Model:     SanDisk SD6SB1M128G1022I   Serial Number:    141218410909   LU WWN Device Id: 5 001b44 becdaed9d   Firmware Version: X231600   User Capacity:    128,035,676,160 bytes [128 GB]   Sector Size:      512 bytes logical/physical   Device is:        Not in smartctl database [for details use: -P showall]   ATA Version is:   8   ATA Standard is:  ATA-8-ACS revision 6   Local Time is:    Fri Jan 16 08:35:48 2015 CST   SMART support is: Available - device has SMART capability.   SMART support is: Enabled  

从上面可以看出,硬盘型号为SanDisk SD6SB1M128G1022I,容量为128GB

 

二、磁盘阵列 RAID模式

如果该机有做磁盘阵列,那么运行上述命令会报错,得不到你要的磁盘信息。可以借助MegaCli命令

MegaCli命令系统不自带,需要额外下载,

下载地址:

http://www.lsi.com/downloads/Public/RAID%20Controllers/RAID%20Controllers%20Common%20Files/8.07.14_MegaCLI.zip

下载之后解压,

unzip CSA1.5-MegaCli_REL80571.zip

cd MegaCLI/MegaCli_Linux

rpm -ivh MegaCli-8.05.71-1.noarch.rpm

 

安装完成

ln -s /opt/MegaRAID/MegaCli/MegaCli64 /usr/bin/

默认安装在/opt下面,建立软链到/usr/bin

[html] view plain copy   [root@localhost bin]# /opt/MegaRAID/MegaCli/MegaCli64 -PDlist -aALL      Adapter #0      Enclosure Device ID: 32   Slot Number: 0   Drive's position: DiskGroup: 0, Span: 0, Arm: 0   Enclosure position: 1   Device Id: 0   WWN: 50000C0F02E57BE9   Sequence Number: 2   Media Error Count: 0   Other Error Count: 0   Predictive Failure Count: 0   Last Predictive Failure Event Seq Number: 0   PD Type: SAS      Raw Size: 279.396 GB [0x22ecb25c Sectors]   Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]   Coerced Size: 278.875 GB [0x22dc0000 Sectors]   Sector Size:  0   Firmware state: Online, Spun Up   Device Firmware Level: D1S6   Shield Counter: 0   Successful diagnostics completion on :  N/A   SAS Address(0): 0x50000c0f02e57bea   SAS Address(1): 0x0   Connected Port Number: 0(path0)   Inquiry Data: WD      WD3001BKHG      D1S6WX11E83NU249   FDE Capable: Not Capable   FDE Enable: Disable   Secured: Unsecured   Locked: Unlocked   Needs EKM Attention: No   Foreign State: None   Device Speed: 6.0Gb/s   Link Speed: 6.0Gb/s   Media Type: Hard Disk Device   Drive Temperature :31C (87.80 F)   PI Eligibility:  No   Drive is formatted for PI information:  No   PI: No PI   Port-0 :   Port status: Active   Port's Linkspeed: 6.0Gb/s   Port-1 :   Port status: Active   Port's Linkspeed: Unknown   Drive has flagged a S.M.A.R.T alert : No            Enclosure Device ID: 32   Slot Number: 1   Drive's position: DiskGroup: 0, Span: 0, Arm: 1   Enclosure position: 1   Device Id: 1   WWN: 50000C0F028F32ED   Sequence Number: 2   Media Error Count: 0   Other Error Count: 0   Predictive Failure Count: 0   Last Predictive Failure Event Seq Number: 0   PD Type: SAS      Raw Size: 279.396 GB [0x22ecb25c Sectors]   Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]   Coerced Size: 278.875 GB [0x22dc0000 Sectors]   Sector Size:  0   Firmware state: Online, Spun Up   Device Firmware Level: D1S6   Shield Counter: 0   Successful diagnostics completion on :  N/A   SAS Address(0): 0x50000c0f028f32ee   SAS Address(1): 0x0   Connected Port Number: 1(path0)   Inquiry Data: WD      WD3001BKHG      D1S6WX11E83VD242   FDE Capable: Not Capable   FDE Enable: Disable   Secured: Unsecured   Locked: Unlocked   Needs EKM Attention: No   Foreign State: None   Device Speed: 6.0Gb/s   Link Speed: 6.0Gb/s   Media Type: Hard Disk Device   Drive Temperature :31C (87.80 F)   PI Eligibility:  No   Drive is formatted for PI information:  No   PI: No PI   Port-0 :   Port status: Active   Port's Linkspeed: 6.0Gb/s   Port-1 :   Port status: Active   Port's Linkspeed: Unknown   Drive has flagged a S.M.A.R.T alert : No            Enclosure Device ID: 32   Slot Number: 2   Drive's position: DiskGroup: 0, Span: 0, Arm: 2   Enclosure position: 1   Device Id: 2   WWN: 50000C0F02E5B8ED   Sequence Number: 2   Media Error Count: 0   Other Error Count: 0   Predictive Failure Count: 0   Last Predictive Failure Event Seq Number: 0   PD Type: SAS      Raw Size: 279.396 GB [0x22ecb25c Sectors]   Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]   Coerced Size: 278.875 GB [0x22dc0000 Sectors]   Sector Size:  0   Firmware state: Online, Spun Up   Device Firmware Level: D1S6   Shield Counter: 0   Successful diagnostics completion on :  N/A   SAS Address(0): 0x50000c0f02e5b8ee   SAS Address(1): 0x0   Connected Port Number: 2(path0)   Inquiry Data: WD      WD3001BKHG      D1S6WX11E83NU081   FDE Capable: Not Capable   FDE Enable: Disable   Secured: Unsecured   Locked: Unlocked   Needs EKM Attention: No   Foreign State: None   Device Speed: 6.0Gb/s   Link Speed: 6.0Gb/s   Media Type: Hard Disk Device   Drive Temperature :28C (82.40 F)   PI Eligibility:  No   Drive is formatted for PI information:  No   PI: No PI   Port-0 :   Port status: Active   Port's Linkspeed: 6.0Gb/s   Port-1 :   Port status: Active   Port's Linkspeed: Unknown   Drive has flagged a S.M.A.R.T alert : No               Exit Code: 0x00  

 

从上面可以看出,该机有三块硬盘,型号为,

WD      WD3001BKHG      D1S6WX11E83NU249,容量为300GB。

 

MegaCli常用参数介绍  MegaCli -adpCount 【显示适配器个数】 MegaCli -AdpGetTime –aALL 【显示适配器时间】 MegaCli -AdpAllInfo -aAll 【显示所有适配器信息】 MegaCli -LDInfo -LALL -aAll 【显示所有逻辑磁盘组信息】 MegaCli -PDList -aAll 【显示所有的物理信息】 MegaCli -AdpBbuCmd -GetBbuStatus -aALL |grep ‘Charger Status’ 【查看充电状态】 MegaCli -AdpBbuCmd -GetBbuStatus -aALL【显示BBU状态信息】 MegaCli -AdpBbuCmd -GetBbuCapacityInfo -aALL【显示BBU容量信息】 MegaCli -AdpBbuCmd -GetBbuDesignInfo -aALL 【显示BBU设计参数】 MegaCli -AdpBbuCmd -GetBbuProperties -aALL 【显示当前BBU属性】 MegaCli -cfgdsply -aALL 【显示Raid卡型号,Raid设置,Disk相关信息】

磁带状态的变化,从拔盘,到插盘的过程中。  Device |Normal|Damage|Rebuild|Normal Virtual Drive |Optimal|Degraded|Degraded|Optimal Physical Drive |Online|Failed –> Unconfigured|Rebuild|Online